RV Repair Winter Garden provides mobile rv propane system inspection throughout Orange, Lake, and Osceola counties. Our certified technician comes to your wherever your RV is parked. Flat-rate pricing quoted before we start - no towing required.
Our certified mobile technicians provide rv propane system inspection throughout Winter Garden and all of Orange, Lake, and Osceola counties. We come to your wherever your RV is parked - no towing, no shop drop-off required.
Feat Ac Repair in Winter Garden, FLFeat Slide Out in Winter Garden, FL
Flat-rate pricing is given before any work begins. You approve the price, we do the work. Available 7 days a week, 7 AM to 8 PM.
How Our RV Propane System Inspection Service Works
1Call us with the details. Tell us about the rv propane system inspection issue and where your RV is located. We provide a flat-rate quote over the phone.
2Tech dispatched to your location. A certified technician drives to your wherever your RV is parked with the tools and parts needed.
3Repaired on-site, same day. Most rv propane system inspection jobs are completed in a single visit. No waiting, no shop drop-off, no towing fees.
4Pay only what was quoted. The price you approved upfront is the price you pay. No surprise charges after the fact.
A propane system inspection including pressure test and leak check runs $75 to $125 on a mobile call. When combined with an annual or pre-purchase inspection, the propane check is included at no additional charge.
We check LP regulator output pressure (should be 11 inches WC), leak-test all visible connections and appliance fittings with a calibrated combustible gas detector, verify all manual shutoff valves operate correctly, inspect the regulator for corrosion and date (regulators should be replaced every 15 years), and confirm all appliance pilots or DSI igniters function.
A sulfur or rotten egg smell inside the RV is the primary indicator - LP gas has an odorant (ethyl mercaptan) added specifically for leak detection. If you smell gas, turn off the tank valve, open all windows, do not activate any switches, exit the RV, and call us. A combustible gas detector mounted near the floor provides continuous monitoring.
Annual inspection is the standard recommendation. Flexible hose sections should be replaced every 5 to 7 years - Florida's UV and heat accelerate rubber hose degradation. Copper tubing rigid runs are long-lived but connection fittings should be checked annually for corrosion.
RV appliances are designed for 11 inches water column (WC), which is roughly 0.4 PSI. This is the standard output of a two-stage RV regulator.
Too low (regulator failing or nearly empty tank) causes appliances to run poorly. Too high (failed regulator) is a safety hazard - safety valves may open and appliances overheat.
Treat it as a real alarm until proven otherwise. Turn off the LP tank valve and ventilate the RV. Check that the detector is not past its service life (most expire in 5 to 7 years from the manufacture date on the unit).
A false alarm from a failing old detector is common; an actual gas leak without perceptible odor is possible if the leak is very small. Call for a leak test.
DOT LP gas cylinders (the portable tanks on travel trailers) must be recertified every 12 years from manufacture date - look for the date stamped on the collar. ASME tanks (fixed tanks on motorhomes) do not require recertification but should be visually inspected annually. Recertification testing is done by LP gas dealers.
Yes - a regulator that has drifted below 11 inches WC output provides insufficient pressure for appliance ignition. Water heater, furnace, and stovetop may fail to light or light weakly. Testing regulator output with a manometer takes 10 minutes and definitively confirms whether pressure is the issue.
Two-stage regulators are standard on all modern RVs because they provide stable output pressure across a wide range of input (tank) pressures - from a full tank to a nearly empty tank. Single-stage regulators (older or aftermarket equipment) allow output pressure to drop as tank pressure drops, causing appliance performance issues near end of tank.
Yes - propane appliances operate safely in Florida heat. The primary summer propane concern is LP tank overpressure from high ambient temperatures. LP tanks are equipped with pressure relief valves that vent if tank pressure exceeds safety limits.
Never paint LP tanks a dark color, which absorbs heat and raises pressure. Keeping tanks in a ventilated compartment out of direct sun is best practice.
FAQ
Common Questions
A propane system inspection including pressure test and leak check runs $75 to $125 on a mobile call. When combined with an annual or pre-purchase inspection, the propane check is included at no additional charge.
We check LP regulator output pressure (should be 11 inches WC), leak-test all visible connections and appliance fittings with a calibrated combustible gas detector, verify all manual shutoff valves operate correctly, inspect the regulator for corrosion and date (regulators should be replaced every 15 years), and confirm all appliance pilots or DSI igniters function.
A sulfur or rotten egg smell inside the RV is the primary indicator - LP gas has an odorant (ethyl mercaptan) added specifically for leak detection. If you smell gas, turn off the tank valve, open all windows, do not activate any switches, exit the RV, and call us. A combustible gas detector mounted near the floor provides continuous monitoring.
Annual inspection is the standard recommendation. Flexible hose sections should be replaced every 5 to 7 years - Florida's UV and heat accelerate rubber hose degradation. Copper tubing rigid runs are long-lived but connection fittings should be checked annually for corrosion.
RV appliances are designed for 11 inches water column (WC), which is roughly 0.4 PSI. This is the standard output of a two-stage RV regulator.
Too low (regulator failing or nearly empty tank) causes appliances to run poorly. Too high (failed regulator) is a safety hazard - safety valves may open and appliances overheat.
Treat it as a real alarm until proven otherwise. Turn off the LP tank valve and ventilate the RV. Check that the detector is not past its service life (most expire in 5 to 7 years from the manufacture date on the unit).
A false alarm from a failing old detector is common; an actual gas leak without perceptible odor is possible if the leak is very small. Call for a leak test.
DOT LP gas cylinders (the portable tanks on travel trailers) must be recertified every 12 years from manufacture date - look for the date stamped on the collar. ASME tanks (fixed tanks on motorhomes) do not require recertification but should be visually inspected annually. Recertification testing is done by LP gas dealers.
Yes - a regulator that has drifted below 11 inches WC output provides insufficient pressure for appliance ignition. Water heater, furnace, and stovetop may fail to light or light weakly. Testing regulator output with a manometer takes 10 minutes and definitively confirms whether pressure is the issue.
Two-stage regulators are standard on all modern RVs because they provide stable output pressure across a wide range of input (tank) pressures - from a full tank to a nearly empty tank. Single-stage regulators (older or aftermarket equipment) allow output pressure to drop as tank pressure drops, causing appliance performance issues near end of tank.
Yes - propane appliances operate safely in Florida heat. The primary summer propane concern is LP tank overpressure from high ambient temperatures. LP tanks are equipped with pressure relief valves that vent if tank pressure exceeds safety limits.
Never paint LP tanks a dark color, which absorbs heat and raises pressure. Keeping tanks in a ventilated compartment out of direct sun is best practice.
RV Problem? We Come to You.
Same-day service across Winter Garden and all of Central Florida. Guaranteed flat-rate pricing before we start.